Analog camera cables prone to breakage

The system manufacturer reported "abnormal operation," and we received the equipment for investigation.

So we checked it with our equipment,

  • When continuous imaging is performed, a timeout anomaly occurs after a while.
  • Shaking the camera causes abnormal image distortion.

I was impatient with the unfamiliar symptom of "I'm in a hurry.

I CONNECTED IT TO THE SECOND CH TO TRY IT OUT, AND THE SYMPTOMS STOPPED IMMEDIATELY.

Conclusion: Disconnection of camera cable

We confirmed with Lynx that "there are not a few reports of disconnections among users who use them for experimental purposes and frequently plug and unplug them.

It is true that the inside of an analog camera cable has an unusual structure, and it is undeniable that it is prone to breakage. Please be careful, especially if you are using them for moving parts.

Leave a comment